UV, VIS, and NIR Spectrometers
Spectrometers enable precise analysis of the spectral composition of light. They provide critical information on light sources, lasers, materials, chemical processes, and optical systems. For reliable measurement results, spectral range, spectral resolution, sensitivity, stray light suppression, and integration complexity must be matched to the specific measurement task.
TOPAG offers the ARIS, NYLIS, and SIENA spectrometers from Avenir Photonics as compact solutions for UV, VIS, and NIR measurement tasks from 185 to 2100 nm. The systems combine high-performance Czerny-Turner optics with integrated signal processing, compact dimensions, and flexible configuration options for research, portable measurement devices, and industrial OEM applications.
ARIS is designed for sensitive UV/VIS and VIS/NIR measurements. NYLIS provides particularly high spectral resolution for narrow lines and laser radiation. SIENA extends into the extended near-infrared range up to 2100 nm with an uncooled InGaAs sensor.
ARIS provides high sensitivity, low stray light, and six flexible spectral ranges for UV/VIS, VIS, and NIR measurements.
NYLIS is the high-resolution spectrometer for the precise analysis of narrow spectral lines, laser sources, and fine spectral structures.
SIENA enables compact NIR spectroscopy up to 2100 nm with an uncooled InGaAs line sensor.
Matched accessories allow ARIS, NYLIS, and SIENA to be optimally adapted to your measurement task.
Key Features of Our Spectrometers
With ARIS, NYLIS, and SIENA, spectrometers are available for measurement tasks from the ultraviolet range at 185 nm to the extended near-infrared range at 2100 nm.
ARIS combines high sensitivity with good resolution. NYLIS achieves resolutions down to 0.06 nm FWHM. SIENA captures broad NIR spectral features up to 2100 nm.
Compact housings, integrated electronics, and USB and UART interfaces enable integration into laboratory setups, portable analytical instruments, and industrial OEM systems.
Interchangeable entrance slits, SMA fiber connectors, and various detectors allow individual adaptation to your measurement task.
ARIS – Characteristics and Design
Compact UV/VIS Spectrometer with High Sensitivity
The ARIS spectrometer from Avenir Photonics combines laboratory-grade performance with the requirements of compact, portable, and industrially integrated measurement systems. Its high-throughput, symmetrical Czerny-Turner design enables high light throughput in a compact form factor.
ARIS is designed for applications requiring high sensitivity, reliable spectral measurement, and flexible integration. According to the manufacturer, the spectrometer achieves two to four times higher sensitivity than comparable spectrometers in the same price range.
Optimized stray light suppression supports precise measurements at high absorbance values. The specified stray light value is 0.08%. The integrated electronics handle automatic exposure control, averaging, buffering, and processing of acquired spectra.
Flexible Configuration for Different Spectral Ranges
ARIS is available in six standard configurations. The choice depends on the required wavelength range, spectral resolution, and available light level. The symmetrical Czerny-Turner design with a 50 mm focal length combines high light throughput with a compact form factor.
Key Specifications of the ARIS Spectrometer
ARIS UV
For applications in the short-wavelength UV range with high spectral resolution
- Wavelength range: 185–420 nm
- Spectral resolution:33 nm typ. / 0.40 nm max. FWHM
- Standard entrance slit: 20 µm
ARIS UV/VIS
Covers the UV and visible ranges for versatile UV/VIS measurement tasks
- Wavelength range: 185–550 nm
- Spectral resolution:40 nm typ. / 0.60 nm max. FWHM
- Standard entrance slit: 20 µm
ARIS VIS
Spectral analysis in the visible range for optical and industrial applications
- Wavelength range: 350–840 nm
- Spectral resolution:60 nm typ. / 0.70 nm max. FWHM
- Standard entrance slit: 20 µm
ARIS VIS/NIR
Covers the visible and near-infrared range for flexible spectral analysis
- Wavelength range: 510–1020 nm
- Spectral resolution:80 nm typ. / 1.00 nm max. FWHM
- Standard entrance slit: 20 µm
ARIS Wide
Broadband UV–VIS–NIR spectroscopy for a wide measurement range
- Wavelength range: 185–1000 nm
- Spectral resolution:00 nm typ. / 1.20 nm max. FWHM
- Standard entrance slit: 20 µm
ARIS Wide NIR
Broadband spectrometer for VIS and NIR spectral analysis up to 1100 nm
- Wavelength range: 300–1100 nm
- Spectral resolution:10 nm typ. / 1.40 nm max. FWHM
- Standard entrance slit: 20 µm
NYLIS – Characteristics and Design
Highest Spectral Resolution for Narrow Lines and Laser Sources
The NYLIS spectrometer was developed for measurement tasks where spectral resolution is the priority. With resolution down to 0.06 nm FWHM, NYLIS enables detailed analysis of narrow spectral lines and closely spaced spectral features.
The symmetrical Czerny-Turner design with a standard 10 µm entrance slit is designed for high spectral resolving power. This makes NYLIS particularly suitable for characterizing narrowband laser sources, investigating emission lines, and demanding scientific spectroscopy.
NYLIS complements ARIS in a targeted way. While ARIS is optimized for high sensitivity and flexible UV/VIS applications, NYLIS focuses on the precise resolution of fine spectral structures. Due to its longer focal length and narrower entrance slit, NYLIS is less sensitive than ARIS and is especially suitable when spectral resolution is more important than maximum signal sensitivity.
Flexible Configuration for High-Resolution Spectral Analysis
NYLIS is available in eleven standard configurations. The spectral ranges are matched to typical laser wavelengths, narrow emission lines, and high-resolution measurement tasks. The 120 mm focal length supports high spectral resolving power and enables resolutions down to 0.06 nm FWHM.
Key Specifications of the NYLIS Spectrometer
NYLIS 380–540
For high-resolution spectral analysis in the near-UV and visible range up to green
- Wavelength range: 380–540 nm
- Spectral resolution:09 nm typ. / 0.11 nm max. FWHM
- Standard entrance slit: 10 µm
NYLIS 380–750
Broad visible spectral range for analysis of optical emissions and light sources
- Wavelength range: 380–750 nm
- Spectral resolution:19 nm typ. / 0.23 nm max. FWHM
- Standard entrance slit: 10 µm
NYLIS 400–500
Compact blue spectral range with particularly high spectral resolution
- Wavelength range: 400–500 nm
- Spectral resolution:06 nm typ. / 0.07 nm max. FWHM
- Standard entrance slit: 10 µm
NYLIS 470–630
For high-resolution measurements from the blue to the red spectral range
- Wavelength range: 470–630 nm
- Spectral resolution:09 nm typ. / 0.11 nm max. FWHM
- Standard entrance slit: 10 µm
NYLIS 500–600
For green and yellow light sources and narrow emission lines
- Wavelength range: 500–600 nm
- Spectral resolution:06 nm typ. / 0.07 nm max. FWHM
- Standard entrance slit: 10 µm
NYLIS 580–740
For high-resolution spectral analysis in the yellow to red range
- Wavelength range: 580–740 nm
- Spectral resolution:09 nm typ. / 0.11 nm max. FWHM
- Standard entrance slit: 10 µm
NYLIS 620–700
For narrowband red light sources and laser applications
- Wavelength range: 620–700 nm
- Spectral resolution:06 nm typ. / 0.07 nm max. FWHM
- Standard entrance slit: 10 µm
NYLIS 740–810
For the transition from the visible to the near-infrared spectral range
- Wavelength range: 740–810 nm
- Spectral resolution:06 nm typ. / 0.07 nm max. FWHM
- Standard entrance slit: 10 µm
NYLIS 750–1100
Broad NIR spectral range for high-resolution measurement tasks up to 1100 nm
- Wavelength range: 750–1100 nm
- Spectral resolution:20 nm typ. / 0.24 nm max. FWHM
- Standard entrance slit: 10 µm
NYLIS 800–860
Narrow NIR spectral range with particularly high spectral resolution
- Wavelength range: 800–860 nm
- Spectral resolution:06 nm typ. / 0.07 nm max. FWHM
- Standard entrance slit: 10 µm
NYLIS 965–1100
For high-resolution spectral measurements in the near-infrared range
- Wavelength range: 965–1100 nm
- Spectral resolution:09 nm typ. / 0.11 nm max. FWHM
- Standard entrance slit: 10 µm
SIENA – Characteristics and Design
Compact NIR Spectrometer up to 2100 nm
The SIENA spectrometer enables measurements in the extended near-infrared range up to 2100 nm. It combines the flexibility of an array spectrometer with a compact form factor, low power consumption, and the reliability required for portable and industrial applications.
The uncooled InGaAs line sensor with integrated dark current compensation enables measurements up to 2100 nm at room temperature. Active sensor cooling and its associated fan are not required. This reduces size, power consumption, and integration effort.
SIENA offers high dynamic range, good sensitivity, and stray light suppression of 0.08%. This makes the system suitable for NIR measurement tasks where material information, absorption bands, or process changes need to be reliably captured.
Flexible Configuration for Different NIR Measurement Ranges
SIENA is available in three standard configurations. The variants differ in their covered spectral range and achievable spectral resolution. The symmetrical Czerny-Turner design with a 30 mm focal length enables a compact form factor with high light throughput.
Key Specifications of the SIENA Spectrometer
SIENA 1.7
For NIR measurements up to 1700 nm with the highest spectral resolution among the standard SIENA variants
- Wavelength range: 850–1700 nm
- Spectral resolution: 8 nm typ. / 10 nm max. FWHM
- Standard entrance slit: 20 µm
SIENA 1.9
For an extended NIR spectral range from 800 to 1900 nm
- Wavelength range: 800–1900 nm
- Spectral resolution: 11 nm typ. / 13 nm max. FWHM
- Standard entrance slit: 20 µm
SIENA 2.1
For measurement tasks in the extended near-infrared range up to 2100 nm
- Wavelength range: 900–2100 nm
- Spectral resolution: 12 nm typ. / 15 nm max. FWHM
- Standard entrance slit: 20 µm
Finding the Right Spectrometer Configuration for Your Measurement Task
TOPAG is happy to support you in selecting a custom configuration that is optimally matched to your spectral range, signal level, desired spectral resolution, measurement geometry, and integration requirements.
Key Specifications of Spectrometer Accessories
Cosine Corrector
Defined light collection for irradiance measurements
- Acceptance angle: 180°
- Characteristic: Nearly cosine-dependent angular response
- Function: Defined light collection
- Suitable for: Irradiance, light source, and spectral measurements
Fiber-Optical Patch Cables
Connecting light sources, sampling optics, and ARIS spectrometers
- Connectors: SMA905
- Versions: Various optical fibers
- Protection: Rubber protective caps
- Option: Custom fiber configurations on request
SMA Collimator
Flexible collimation of divergent fiber output
- Connector: SMA
- Function: Collimation and fiber coupling
- Adjustable: Field of view and light collection
- Suitable for: Fiber-coupled spectroscopy
User-Replaceable Entrance Slits
Adjustment of spectral resolution and light throughput
- Slit widths: 10, 20, 50, 75, 100, 150, 200, and 300 µm
- Function: Adjustment of resolution and light throughput
- Suitable for: Different spectral applications and measurement conditions
Direct-Attach Collimator
Combines collimator and entrance slit in a single unit
- Integrated entrance slit: 20 / 50 / 100 µm
- Direct mounting: To the spectrometer
- Function: Light collection and collimation
- Suitable for: Compact and fiber-coupled measurement setups
FAQ – UV, VIS, and NIR Spectrometers
What Distinguishes ARIS, NYLIS, and SIENA?
ARIS combines high sensitivity, low stray light, and flexible configurations for versatile UV/VIS measurements. NYLIS achieves spectral resolution down to 0.06 nm FWHM and is particularly well suited to laser lines and fine spectral structures. SIENA uses an uncooled InGaAs sensor for NIR measurements up to 2100 nm.
What Applications Are the Spectrometers Suitable For?
The ARIS, NYLIS, and SIENA spectrometers cover UV/VIS and NIR measurement tasks from 185 to 2100 nm. Typical applications of the three models include:
- UV/VIS absorbance and transmission measurements: Analysis of liquids, filters, coatings, and materials with ARIS.
- Light source and component characterization: Spectral investigation of LEDs, lamps, optical components, and broadband sources with ARIS.
- Laser characterization: High-resolution analysis of narrow spectral lines, line spacing, and side modes with NYLIS.
- NIR material analysis: Investigation of moisture, composition, and quality parameters up to 2100 nm with SIENA.
- Process monitoring and OEM sensing: Integration of ARIS or SIENA into compact measurement devices and industrial sensor systems.
What Wavelength Ranges Do the Spectrometers Cover?
ARIS covers, depending on configuration, ranges from 185 to 1100 nm. NYLIS is available for spectral ranges from 380 to 1100 nm. SIENA measures in the near-infrared range from 800 to 2100 nm.
Why Is Entrance Slit Width Important?
The entrance slit width affects light throughput and spectral resolving power. A narrower slit improves the ability to resolve closely spaced lines but reduces the light reaching the detector. A wider slit increases light throughput but produces broader spectral lines.
Are ARIS, NYLIS, and SIENA Suitable for Industrial OEM Applications?
Yes. The spectrometers are designed for compact measurement systems, portable devices, and industrial integration. They feature integrated automatic exposure control, averaging, buffering, and spectrum processing. USB 2.0 Full Speed and UART are available as standard.
Can Custom Wavelength Ranges Be Realized?
In addition to the standard configurations, application-specific wavelength ranges and optical adaptations are possible. The technical design depends, among other factors, on the detector, diffraction grating, entrance slit, light source, and required spectral resolution.
What Should Be Considered When Measuring High Absorbance Values?
For high absorbance measurements, stray light, dynamic range, reference measurement, light source, and optical measurement geometry are particularly important. ARIS and SIENA specify a stray light value of 0.08%. For reliable measurement results, however, the entire measurement setup must be matched to the sample, wavelength range, and desired measurement accuracy.